TECHNICAL FEATURES

 

v  The Deflection structure of crankshaft and connect rod: the plunger pump crankshaft center is lower than the crosshead centerline by certain distance. The positive pressure between the crosshead and sleeve is reduced by 24% around compared to normal ones. Reduction of the crosshead-sleeve friction helps to improve the transmission efficiency and reliability.

v  Install spacer frame between power end and fluid end. Ensuring that the crosshead slide hole and plunger packing are connected concentrically. Reducing wear at the crosshead and plunger packing.

v  Super combined nut: For the connection between pump frame and module, therefore tightening a big nut can be decomposed into tightening a circle of small screws. Intensity of manual operation is remarkably reduced.

 

TECHNICAL PARAMETERS

Type

QPI-2500

Rated input power   (kW)   

1864 (2500 hp)

Stroke length  (mm) 

203.2

Rated stroke   (r/min)    

115

Max. Stroke  (r/min) 

330

Plunger diameter(inch)

4″

4 1/2″

5″

Max. Discharge pressure  (MPa)      

105.5

83.4

67.5

Max. Displacement (L/s) 

45.30

57.34

70.79

Max plunger rod load (N)

855,505

Gear ratio

6.278:1

Weight of single pump (kg)   

7.95

 

Plunger diameter

The displacement and pressure under different stroke

115

150

200

250

300

330

in

mm

L/s

MPa

L/s

MPa

L/s

MPa

L/s

MPa

L/s

MPa

L/s

MPa

4

101.6

15.79

105.5

20.59

81.5

27.46

61.1

34.32

48.9

41.19

40.7

45.30

37.0

4.5

114.3

19.98

83.4

26.06

64.4

34.75

48.3

43.44

38.6

52.12

32.2

57.34

29.3

5

127.0

24.67

67.5

32.18

52.1

42.90

39.1

53.63

31.3

64.35

26.1

70.79

23.7

 

 

Note1.Data in the table based on the continuous operating conditionscalculated at 90% mechanical efficiency and 100% volumetric efficiency

 