1P7ML52211BA12/7ML52211BA18
2018-09-23 11:22 Click£ºtimes
2 | Conflex hose | Sub-base area | Replacement | 2"X30' £»3-1/2"X45'£»3-1/2"X5m STAINLESS STEEL ARMOR COVERED FIRE RESISTANT CHOCK AND KILL LINE HOSE 10000PSI WP, 15000PSI TEST PRESSURE COUPLED WITH 2-1/16" £» 4-1/16" 10K FLANGED END |
3 | Remote Panel for the BOP trolley | Sub-base area | Replacement | ¡¡ |
4 | Complete BOP and BOP Hydraulic hoses | Sub-base area | Replacement | High-pressure control hose 1"*5000psi*10Meter Length*24ea |
5 | BOP Hydraulic Trolley hoses | Sub-base araea | Replacement | ¡¡ |
9 | Air hoses under the sub-base | Sub-base area | Replacement | Hose 38¢ñ-2000C, 1300030899 |
¡¡ | ¡¡ | ¡¡ | ¡¡ | Hose 38¢ñ-4000C, 1300017624 |
¡¡ | ¡¡ | ¡¡ | ¡¡ | Hose 25¢ñ-7000C, 1300023246 |
14 | Raising Line integrity | Off driller’s side | Replacement | Raising line, φ72×50m, 1300094622, Qty: 2 pcs/set |
15 | Choke Manifold gauges | Beside Drill tank | Replacement | ¡¡ |
16 | Shaker Tank Junction Box | Mud Section | Replacement | ¡¡ |
20 | Agitator Motor | Mud section | Replacement | Agitator 5.5kW NJ5.5 |
Agitator 15kW NJ15 | ||||
22 | Three Flame detector | Mud section | Replacement | SPXCDALMFX£¨cable included) |
23 | Three H2S Gas detector | Mud section | Replacement | SPXCDALMHX£¨cable included) |
24 | Cables of camera | Mud section | Replacement | vedio cables 10×0.75+SYWV-75-5 |
25 | Three Trip tank pit sensors | Mud section | Replacement | 1P7ML52211BA12/7ML52211BA18 |
26 | Horn and cable | Mud section | Replacement | Telephone system (cable included,60038-101) |
28 | Jumper pipe hose | Beside sub-base area | Replacement |
High pressure hose: 3 1/2”×4.5m×35MPa, 5” 1002F/M, F2, oil base, 1300104674 |
30 | Mud Pump Motor | Mud section area | Replacement | AC rig123.net' target='_blank'>DRILLING MOTOR, Model: HTB12A1, right rotation blower. Rated Power=1200KW, Rated current=1520A, RPM=425r/min, Rated voltage=575V, Rated torque=22684N.m, Max.speed=505r/min, Insulation class=H, Rated frequency=57Hz |
¡¡ | Mud pump junction box | Mud section area | Replacement | ¡¡ |
31 | Mud pump A liner wash motor | Mud section area | Replacement | Liner wash pump, IRG40-100, 1300005299 |
32 | Mud pump A Lub oil pump & cables | Mud section | Replacement | Lub oil pump, KCB55, 1300023781 |
33 | Mud pump B liner wash motor | Mud section area | Replacement | Liner wash pump, IRG40-100, 1300005299 |
34 | Mud pump B Lub oil pump & cables | Mud section | Replacement | Lub oil pump, KCB55, 1300023781 |
35 | All cables from mud pumps,mud tanks and auxiliary motors to the VFD | VFD & Mud section area | Replacement | Refer to quotation for cables. |
36 | Cable trays along VFD connections | VFD & Mud section area | Replacement | Refer to quotation for cables. |
37 | Telephone panels , Horn Speaker and Starter cables | Mud section area | Replacement | Telephone system (cable included,60038-101) |
39 | All the cables from the VFD 1 and 2 to the grasshopper are completed burnt and damaged. | VFD and Grasshopper area | Replacement | Refer to quotation for cables. |
40 | All the TDS service cable | Drilling section | Replacement | Refer to quotation for cables. |
41 | TDS control cable to the VFD and driller’s console | Drilling section | Replacement | Refer to quotation for cables. |
42 | TDS signal cable | Drilling section | Replacement | Refer to quotation for cables. |
43 | Rotary table cable | Drilling section | Replacement | Refer to quotation for cables. |
44 | All the small cables on the grasshopper | Drilling section | Replacement | Refer to quotation for cables. |
47 | All Signal ,power and lighting cables from the grasshopper to the rig floor.( Less than 600V) | Under the sub structure | Replacement | Refer to quotation for cables. |
48 | BOP control cable from rig floor to the BOP room | Unser sub structure | Replacement | Refer to quotation for cables. |
50 | Logging power cable | Shaleshaker tank | Replacement | Refer to quotation for cables. |
51 | TDS-VFD COMPUTER SCREEN, MODEL PPC-L128T-R81-XE, INPUT 12-24VDC, 5-3.75A, S/N C2 | TDS VFD Room | Replacement | PPC-3120S;12 inches,software included |
52 | PLC CPU: SIMATIC S7-300, TYPE CPU 315-2PN/DP, FOR VFD - URGENT | VFD 1 | Replacement | S7300CPU;6ES7;315-2EH14-0AB0,software included |
53 | PRESSUR E/LIQUID LEV EL TRANSMITTER, TYPE JYB-KB-KAG, MODEL JYB, RANGE 0-70 Mpa, DC 24V, ACCURACY ±0.2% damaged by fire heat | Driller’s console | Replacement | JYB-KB-KAG;0-70MPa |
54 | Touch screen | Driller’s console | Replacement | 6AV2124-0QC02-0AX0,software included |
55 | Mud Pump main bearing end cover sealing gasket ‘4pcs’. | Mud Pump | Replacement | Mud Pump main bearing end cover NB100.02.01.00£»Sealing gasket NB100.02.03 |
56 | Mud Pump cross head cover & sealing gasket ‘4pcs’. | Mud Pump | Replacement | Mud Pump cross head cover NB100.04.16£»Sealing gasket ‘NB100.04.04 |
56 | ROTARY TABLE MOTOR | Rotary table | Replacement |
AC DRILLING MOTOR, Model: HTB02B, left side junction box, right side left rotation blower. Rated Power=600KW, Rated urrent=745/714A, RPM=660r/min, Rated voltage=575/600V, Rated torque=8686N.m, Max.speed=1060r/min, Insulation class=H, Rated frequency=33.5Hz |
57 | SHOCK-Resistant pressure gauge for Mud pump , BOP test pump gauge, pressure switch, air flow senor | Mud Pump | Replacement | ¡¡ |
TAG£º