Your location£ºhome > News > Product info >

Rosemount Rosemount 3051L Flange Mounted Level Transmitter

2019-04-28 17:44      Click£ºtimes
Rosemount Rosemount 3051L Flange Mounted Level Transmitter
model
product name
3051L
Flange mounted level transmitter
Code
Pressure range (range/minimum range)
2
-250 to 250 inH2O/2.5H2O (-62.2 KPa to 62.2 KPa/0.62 KPa)
3
-1000 to 1000 inH2O/10H2O (-248KPa to 248KPa/2.5KPa)
4
-8310 to 8310 inH2O/83.1H2O (-2070KPa to 2070KPa/20.7KPa)
Code
Output
A
4-20mA with digital signal based on HART protocol
M
Low power, 1-5VDC with HART-based digital signal (0.8-3.2VDC output option code C2)
F
FF bus
W
PROFIBUS
Code
Isolation diaphragm size
material
Extending length
Comment
G0
2in./DN 50
316L SST
Only flat


The diameter of the extension is in accordance with the Schedule 80 pipe size. Consult the factory for the Schedule 40 pipe size.
H0
2in./DN 50
Hastelloy C-276
Only flat
J0
2in./DN 50
îã
Only flat
A0
3in./DN 80
316L SST
Flat
A2
3in./DN 80
316L SST
2in./50mm
A4
3in./DN 80
316L SST
4in./100mm
A6
3in./DN 80
316L SST
6in./150mm
B0
4in./DN 100
316L SST
Flat
B2
4in./DN 100
316L SST
2in./50mm
B4
4in./DN 100
316L SST
4in./100mm
B6
4in./DN 100
316L SST
6in./150mm
C0
3in./DN 80
Hastelloy C-276
Flat
C2
3in./DN 80
Hastelloy C-276
2in./50mm
C4
3in./DN 80
Hastelloy C-276
4in./100mm
C6
3in./DN 80
Hastelloy C-276
6in./150mm
D0
4in./DN 100
Hastelloy C-276
Flat
D2
4in./DN 100
Hastelloy C-276
2in./50mm
D4
4in./DN 100
Hastelloy C-276
4in./100mm
D6
4in./DN 100
Hastelloy C-276
6in./150mm
E0
3in./DN 80
îã
Only flat
F0
4in./DN 100
îã
Only flat
Code
Mounting flange size
Rated rating
material
Suitable for high pressure side diaphragm size
M
2in.
Level 150
Carbon steel
2 in./DN50
A
3in.
Level 150
Carbon steel
3 in./DN80
B
4in.
Level 150
Carbon steel
4 in./DN100
N
2in.
Level 300
Carbon steel
2 in./DN50
C
3in.
Level 300
Carbon steel
3 in./DN80
D
4in.
Level 300
Carbon steel
4 in./DN100
P
2in
Level 600
Carbon steel
2 in./DN50
E
3in.
Level 600
Carbon steel
3 in./DN80
X
2in.
Level 150
SST
2 in./DN50
F
3in.
Level 150
SST
3 in./DN80
G
4in.
Level 150
SST
4 in./DN100
Y
2in.
Level 300
SST
2 in./DN50
H
3in.
Level 300
SST
3 in./DN80
J
4in.
Level 300
SST
4 in./DN100
Z
2in.
Level 600
SST
2 in./DN50
L
3in.
Level 600
SST
3 in./DN80
Q
DN 50
PN 10-40
Carbon steel
2 in./DN50
R
DN 80
PN 40
Carbon steel
3 in./DN80
S
DN 100
PN 40
Carbon steel
4 in./DN100
V
DN 100
PN 10/16
Carbon steel
4 in./DN100
K
DN 50
PN 10-40
SST
2 in./DN50
T
DN 80
PN 40
SST
3 in./DN80
U
DN 100
PN 40
SST
4 in./DN100
W
DN 50
PN 10/16
SST
4 in./DN100
Code
Process oil filling - high pressure side
Temperature limit
A
Syltherm XLT
-75 to 150 ° C (-102 to 302 ° F)
C
D.C.704 silicone oil
0 to 205 ° C (32 to 401 ° F)
D
D.C.200 silicone oil
-45 to 205 ° C (-49 to 401 ° F)
H
Inert liquid
-45 to 175 ° C (-49 to 347 ° F)
G
Glycerin and water
-15 to 95 ° C (5 to 203 ° F)
N
Neobee M-200
-15 to 205 ° C (5 to 401 ° F)
P
Propylene glycol and water
-15 to 95 ° C (5 to 203 ° F)
Code
Low pressure side structure
Flange joint
Diaphragm material
Filling liquid
11
Gauge
stainless steel
316 SST
Silicone oil
twenty one
Differential pressure
stainless steel
316 SST
Silicone oil
twenty two
Differential pressure
stainless steel
Hastelloy C-276
Silicone oil
2A
Differential pressure
stainless steel
316 SST
Inert liquid (halogenated hydrocarbon)
2B
Differential pressure
stainless steel
Hastelloy C-276
Inert liquid (halogenated hydrocarbon)
31
Far pass
stainless steel
316 SST
Silicone oil (option code S1)
Code
Option
Head
M(1)
Linear head, 0-100% scale
M3(1)
Special scale head, specified range
M4(1)
LCD meter, 0-100%
M7(1)
LCD head, linear, special settings
Hazardous site certification
E5
Canadian Standards Association (CSA) Flameproof Certification
I5(2)
Factory mutual inspection (FM) non-flammable and intrinsically safe certification
K5
Factory mutual inspection (FM) explosion-proof and intrinsic safety certification
C5(3)
Canadian Industry and Science Certification (Canada only)
C6(2)
I6 and E6 combined, CSA flameproof and intrinsically safe certification
(requires maximum supply voltage of 42.4Vdc)
K6
CSA/CENELEC flameproof and intrinsically safe certification
EF(4)
China NEPSI, GB standard flameproof certification
EF(2)(4)
China NEPSI, GB standard intrinsic safety certification
E4
Japanese Industrial Standard (JIS) Flameproof Certification
E7
Australian Standards Association (SAA) Flameproof Certification
E8
CESI/CENELEC flameproof certification
I1(2)
BASEEFA Intrinsically Safe Certification
I7(2)
Australian Standards Association (SAA) Intrinsic Safety Certification
I8(5)
CESI/CENELEC intrinsic safety certification
N1(2)
BASEEFA N certification
N7
Australian Standards Association (SAA) non-flammable safety certification
IC(2)
SEV intrinsic safety certification
Other options
W5
Copper O-ring for vacuum applications (non-fluid parts)
Q4
Calibration data sheet
Q8(6)
Material traceability in accordance with EN 10204 3.1B
L4
316 SST flange and joint bolt
V1
Inverting output
V2
4-20mV test signal
V3
20-100mV test signal
Z1(7)
4-wire, 0-20mA output
Z2(7)
4-wire, 0-16mA output
Z3(7)
4-wire, 0-10mA output
F_
Select a code from the table below to flush the connection options.
Rosemount 3051L Level Transmitter Typical Model:
3051L2AG0RD21AAK5M5Q4
3051L2AH0KD21AAM5

3051L3AA0FD21AB

 

 

Contact email:sales006@rig123.com

Leon Lee